Campbell-scientific CR3000 Micrologger Manual de usuario Pagina 195

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 590
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 194
Section 7. Installation
195
Standard deviation of horizontal wind fluctuations from sub-intervals is calculated
as follows:
where: is the standard deviation over the data-storage interval, and
are sub-interval standard deviations. A sub-interval is
specified as a number of scans. The number of scans for a sub-interval is given
by:
Desiredsubinterval(secs)/scanrate(secs)
For example, if the scan rate is 1 second and the data interval is 60 minutes, the
standard deviation is calculated from all 3600 scans when the sub-interval is 0.
With a sub-interval of 900 scans (15 minutes) the standard deviation is the
average of the four sub-interval standard deviations. The last sub-interval is
weighted if it does not contain the specified number of scans.
The EPA recommends hourly standard deviation of horizontal wind direction
(sigma theta) be computed from four fifteen-minute sub-intervals.
7.8.5.2.1 Measured Raw Data
S
i
: horizontal wind speed
i
: horizontal wind direction
Ue
i
: east-west component of wind
Un
i
: north-south component of wind
N: number of samples
7.8.5.2.2 Calculations
Mean Wind Vector
Resultantmeanhorizo
ntalwindspeed,Ū: