Appendix B. Status Table and Settings
528
Table 120. Common Uses of the Status Table
Feature or
Suspect Constituent
Status Field(s)
to Consult
RS-232Handshaking
RS-232Timeout
CommActive
CommConfig
Baudrate
PakBus
IsRouter
PakBusNodes
(p. 433) (see
CommsMemFree(2)
(p. 433) )
CentralRouters
Beacon
Verify
MaxPacketSize
CRBasic Program
ProgSignature
CompileResults
ProgErrors
VarOutofBound
SkippedScan
SkippedSlowScan
PortStatus
PortConfig
Measurements
ErrorCalib
Data
SkippedRecord
DataFillDays
Table 121. Status-Table Fields and Descriptions
Fieldname Description Variable Type Default Range Edit? Info Type
RecNum
Increments for successive
status-table data records.
0 to 2
32
TimeStamp
Scan time that the record was
generated
Time
OSVersion
Version of the operating
system (OS).
String Status
OSDate
Date OS was released,
YYMMDD
String Status
OSSignature
Operating system signature Integer Status
SerialNumber
CR1000-specific serial
number. Stored in FLASH
memory.
Integer Status
Vista de pagina 527