Campbell-scientific CR1000 Measurement and Control System Manual de usuario Pagina 107

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 588
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 106
Section 7. Installation
107
6. If there is no default.cr1 file or it cannot be compiled, the CR1000 will not
automatically run any program.
7.6.3.5 Network Planner
Figure 45: Network Planner Setup
7.6.3.5.1 Overview
Network Planner allows the user to:
create a graphical representation of a network, as shown in figure Network
Planner Setup
(p. 107).
determine settings for devices and LoggerNet.
program devices and LoggerNet with new settings.
Why is Network Planner needed?
PakBus protocol allows complex networks to be developed.
Setup of individual devices is difficult.
Settings are distributed across a network.
Different device types need settings coordinated.
Caveats
Network Planner aids in, but does not replace, the design process
It aids development of PakBus networks only.
It does not make hardware recommendations.
It does not generate datalogger programs.