Section 7. Creating and Editing Datalogger Programs
12: If time is (P92)
1: 0 minutes into interval
2: 60 minute interval
3: 10 Set high Flag 0(output)
13: Sample (P70)
1: 2 Reps
2: 1 Loc [TempC]
When the program is executed, the datalogger will perform the Sample (P70)
instruction twice. The first time, it will sample the value stored in the TempC
location. The second time, it will sample the value stored in the BatteryV
location.
If an Input Location is inserted between the TempC and BatteryV
location, the inserted location will be sampled instead of BatteryV.
7.4.9 Input Location Editor
Input Location labels can be entered and edited by using the Input Location
Editor. To access the Input Location Editor, select Edit | Input Labels or press
<F5>.
NOTE
7-69