Section 4. Setting up Datalogger Networks
When configuring a SerialPortPool, use the Serial Ports tab to add all the serial
ports that are connected to base modems that can be used to call this site. The
dialing string entered in the phone remote must work in conjunction with any
of the modems connected to the serial ports added to the pool for this
datalogger.
For more information on modem pooling, refer to LoggerNet’s online help.
When using pooled modems, the modems should all be such that
any of the modems/phone lines could be used in conjunction with
any device that has it as part of its modem pool. Using the same
type brand of modem is suggested. Also ensure that there is no
preference for phone lines that may be used (e.g., long distance
rates).
Hardware Tab
Standard
Communications Enabled This check box is used to turn communication on
or off. This check box must be enabled for any communication to take place
over the SerialPortPool.
NOTE
4-47