9 Ice Detector RS-422 String Format
Table 8. Serial String Format
Byte Bit Definition Comments/Interpretation/Range
0 (First) 7 (MSB)
String ID Presently defined as 00
6
May add additional strings in future
5 - 3 Unused
2
Probe Heater State
1- Heater On
0- Heater Off
1
Ice Output
1- Ice
0- No Ice
0 Status Output 1- Fail
0- (OK) No Fail
1 -2 MSO FREQUENCY MSO Count in Hex Frequency = 774060000/Dec (MSO)
3 - ERRSTAT1 7 Unused
1 = Active
6 MSA Fail, Too High
5 MSO Fail, Too Low
4 EEPROM Fail
3 RAM Fail
2 ROM Fail
1 Watchdog Fail
0 Power Interrupt Timer Fail
4 - ERRSTAT2 7 - 6
Probe Heater Failure
00 = Probe Heater OK
01 = Probe Heater Always ON or OPEN
10 = Probe Heater Always OFF
11 = Probe Heater ON with 1 Enable
5 De-Icing Fail
1 = Active
4 Unused
3 Unused
2 Unused
1 Unused
0 Unused