9 Wiring
The wiring of the 0871LH1 will depend on the required communication
outputs of your application. If you require the use of the discrete outputs
of the 0871LH1, then refer to section 9.1. If you require the use of the RS-
422 output, then refer to section 9.2.
Please contact a Certified Electrician to properly install the C2673 power
supply. All electrical connections and housings must be installed by a
Certified Electrician.
9
9.1
0871LH1CBL-L Wiring for Discrete Output
Table 2. Datalogger Connections
Description Pin Colour CR3000/CR1000 CR10X/CR510
Ice F Blue C1 C1
Status G Yellow C2 C2
RS422 A D White N/C N/C
RS422 B E Brown N/C N/C
Power Reference B Black G G
Case GND C Green G G
5V Power Purple 5V 5V
Shield Clear G G
The 5VDC connection must be made to avoid damage to the 0871LH1.
Isolate wires that are not connected as they will cause problems if shorted
to ground.
NOTE:
WARNING:
WARNING:
Table 3. Power Connections to Terminal Expander
Description Pin Colour Connection
24VDC A Red V+
24VDC Return B Black V-