Campbell-scientific 255-100 Novalynx Analog Output Evaporation Gauge Manual de usuario

Busca en linea o descarga Manual de usuario para Instrumentos de medición Campbell-scientific 255-100 Novalynx Analog Output Evaporation Gauge. Campbell Scientific 255-100 Novalynx Analog Output Evaporation Gauge User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
255-100 Novalynx Analog
Output Evaporation Gauge
1/09
Copyright © 2009
Campbell Scientific, Inc.
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - Output Evaporation Gauge

255-100 Novalynx Analog Output Evaporation Gauge1/09Copyright © 2009Campbell Scientific, Inc.

Pagina 2 - Warranty and Assistance

255-100 Novalynx Analog Output Evaporation Gauge DataTable (Hourly,1,-1) DataInterval (0,60,min,10) Sample (1,PanLevel,FP2) Minimum (1,batt_volt,FP

Pagina 3 - 255-100 Table of Contents

255-100 Novalynx Analog Output Evaporation Gauge 02: Beginning of Loop (P87) 1: 0 Delay 2: 5 Loop Count 03: Excite-Delay, SE (P4) 1: 1

Pagina 4

255-100 Novalynx Analog Output Evaporation Gauge (3) Add more water to the evaporation pan and measure the water’s depth in the pan. (4) Measure th

Pagina 5 - Evaporation Gauge

255-100 Novalynx Analog Output Evaporation Gauge between 8 1/2” and 9 1/2” (depending on water pressure). The Electronic Water Timer will enable tank

Pagina 6 - 2. Specifications

255-100 Novalynx Analog Output Evaporation Gauge 10 Assuming you refill the pan once a day and the evaporation rate is 10 mm (1 cm) per day, the amou

Pagina 7

This is a blank page.

Pagina 8 - 4. Wiring

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbells

Pagina 9 - 5. Programming

Warranty and Assistance The 255-100 NOVALYNX ANALOG OUTPUT EVAPORATION GAUGE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in mate

Pagina 10

255-100 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab f

Pagina 12

255-100 Novalynx Analog Output Evaporation Gauge 1. General Novalynx Corporation manufacturers the 255-100 Analog Output Evaporation Gauge and the 25

Pagina 13 - 9. Storage Tank Size

255-100 Novalynx Analog Output Evaporation Gauge 2. Specifications FIGURE 1. 255-100 Connected to 255-200 Using 255-100P/F 255-100 Novalynx Analog

Pagina 14

255-100 Novalynx Analog Output Evaporation Gauge 255-200 Novalynx Class A Evaporation Pan Material: Low carbon stainless steel, type 304, 18 gauge Co

Pagina 15 - This is a blank page

255-100 Novalynx Analog Output Evaporation Gauge NovaLynx Model 255-250 Evaporation Pan Support Platform (Available by Special Order) Wood platform fo

Pagina 16

255-100 Novalynx Analog Output Evaporation Gauge 5. Programming Depending on the model of datalogger, make the measurement using the Excite-Delay SE

Comentarios a estos manuales

Sin comentarios