Campbell-scientific 43347 RTD Temperature Probe and 43502 Aspirated Ra Manual de usuario

Busca en linea o descarga Manual de usuario para Instrumentos de medición Campbell-scientific 43347 RTD Temperature Probe and 43502 Aspirated Ra. Campbell Scientific 43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 40
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
43347 RTD Temperature Probe,
43502 and 41003-5 Radiation
Shields
Revision: 11/13
Copyright © 1994-2013
Campbell Scientific, Inc.
Vista de pagina 0
1 2 3 4 5 6 ... 39 40

Indice de contenidos

Pagina 1 - 43502 and 41003-5 Radiation

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation ShieldsRevision: 11/13 Copyright © 1994-2013Campbell Scientific, Inc

Pagina 2

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields junction box provides terminals for cable connections and properly positions the sens

Pagina 3 - Warranty

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields FIGURE 3-2. 43502 Radiation Shield mounted to a CM200-series Crossarm 43502 ShieldC

Pagina 4 - Assistance

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields 41003-5 ShieldPN 27251 Split Nut43347 Probe FIGURE 3-3. 41003-5 Radiation Shield mou

Pagina 5 - Table of Contents

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields 4. Wiring The 43347 comes in two versions—the “IX” version and the “VX” version. Th

Pagina 6

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields TABLE 4-1. Datalogger Connections Color Wire Label CR10(X), CR510 CR3000, CR1000

Pagina 7

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields TABLE 4-2. 43502 Blower/Tachometer Connections Color 43502 115 Vac/12 DC Transfor

Pagina 8 - 2. Specifications

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields TABLE 5-1. Wiring for Measurement Examples Color Function Datalogger Channels use

Pagina 9 - 3. Installation

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields 'Define Data Tables DataTable(Table1,True,-1) DataInterval(0,60,Min,10) Averag

Pagina 10

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields 7: 1 Loc [ RTD_C ] 8: 1 Mult 9: 0 Offset ;Apply calibration coefficient

Pagina 11

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields 5.2.2 CR10X Example for Uncalibrated 43347-VX Probes ;{CR10X} ; *Table 1 Program 01

Pagina 13 - 4. Wiring

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields When Short Cut software is used to create the datalogger program, wire the sensor to

Pagina 14

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields The 43347-IX is measured with the Resistance measurement instruction with the CR3000

Pagina 15

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields 'CR3000 'Declare Variables and Units Public RTD_Res Public RTD_Cal_C Publ

Pagina 16

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields Const RTD_Ro = 1000.00 'This is the actual RTD resistance for this sensor at 0.

Pagina 17

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields Where: ΔT = self heating in °C Ix = current excitation RRTD = 1000 Ω RTD resis

Pagina 18

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields other solvent. Check mounting bolts periodically for possible loosening due to tower

Pagina 19 - 6.1 Wiring

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields 20

Pagina 20 - 6.2 Datalogger Programming

Appendix A. Example CR10(X) Program for Ice Bath Calibration The following program can be used to calibrate 43347 probes (probes ordered without the

Pagina 21

Appendix A. Example CR10(X) Program for Ice Bath Calibration A-2 6: If (X<=>F) (P89) 1: 3 X Loc [ P9_mult ] 2: 3 >= 3: 100

Pagina 22

Appendix B. 43502 Aspirated Radiation Shield 43347 RTD Temperature Probe 43347 PROBE B-1

Pagina 23

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Pagina 24 - 7. Maintenance

Appendix B. 43502 Aspirated Radiation Shield Grommet Sensor Mounting Bushing FIGURE B-1. 43347 probe and bushing Wiring: TACH – White POS – Red NE

Pagina 25 - 11. References

Appendix C. 43347 Aspirated Radiation Shield C-1

Pagina 26

Appendix C. 43347 Aspirated Radiation Shield The 43408 radiation shield employs concentric downward facing intake tubes and a small canopy shade to i

Pagina 27

Appendix C. 43347 Aspirated Radiation Shield C.2 Installation Refer to the General Assembly drawing in the RM Young 43408 Instruction Manual (include

Pagina 28

Appendix C. 43347 Aspirated Radiation Shield FIGURE C-3. 43408 Aspirated Radiation Shield wiring C-4

Pagina 29

Appendix D. Measure Two 43347-IX Probes Using One Current Excitation Channel One current excitation channel can excite multiple 43347 probes if the

Pagina 30

Appendix D. Measure Two 43347-IX Probes Using One Current Excitation Channel D.1 Wiring Wiring for two 43347-IX probes is shown in FIGURE D-1. Ground

Pagina 31

Appendix D. Measure Two 43347-IX Probes Using One Current Excitation Channel TABLE D-1. Wiring for Two 43347-IX Probes Example Color Function CR30

Pagina 32 - C.1 Specifications

Appendix D. Measure Two 43347-IX Probes Using One Current Excitation Channel D-4 'Measure the 43347-IX probes Resistance(RTD1_Res,1,mV200,1,

Pagina 34

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Pagina 35 - Channel

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Pagina 36 - D.1 Wiring

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Pagina 37

Table of Contents ii 11. References...19 Appendices A. Example CR10(X) Program for Ice

Pagina 38

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields 1. General The -L option on the model 43347 RTD Temperature Probe (43347-L), and th

Pagina 39

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields 2. Specifications 43502 ASPIRATED RADIATION SHIELD Sensor Types: Accommodates senso

Pagina 40

43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields Accuracy: ±0.3°C at 0° C ±0.1°C with NIST calibration Temperature Coefficient: .00

Comentarios a estos manuales