255-100 Novalynx Analog Output Evaporation Gauge
2. Specifications
FIGURE 1. 255-100 Connected to 255-200 Using 255-100P/F
255-100 Novalynx Analog Output Evaporation Gauge
Height: 27 1/2” (700 mm)
Diameter: 8” (203 mm)
Weight: 7 1/2 lbs (3.4 kg)
Shipping weight: 15 lbs (6.8 kg)
Cable: 50' of 3-conductor, 24 AWG, shielded
Float: 4” diameter, plastic
Counterweight: 4 oz (114 g), stainless steel
Water input port: 1/2” NPT coupling, female
Base dimensions: 16” (40.6 cm) triangle with leveling screws
Total resolution: 0.03” (0.76 mm)
Accuracy: 0.25%
Rotation: 360° continuous
Electrical angle: 340°, ±1° (20° gap)
Resistance: 1,000 ohms, ±10%
Operating temperature: -40° to +60°C
Linearity: 0.25%
Mechanical range: 0 to 10” (0 – 254 mm)
Electrical range: 0 to 9.44” (0 – 240 mm)
FIGURE 2. 255-100 Novalynx Analog Output Evaporation Gauge