Campbell-scientific CR800 and CR850 Measurement and Control Systems Manual de usuario Pagina 114

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 566
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 113
Section 7. Installation
114
CRBasicExample6. ProperProgramStructure
'Declarations
'Define Constants
Const RevDiff = 1
Const Del = 0 'default
Const Integ = 250
Const Mult = 1
Const Offset = 0
Declare constants
'Define public variables
Public RefTemp
Public TC(6)
'Define Units
Units RefTemp = degC
Units TC = DegC
Declare public variables,
dimension array, and declare
units.
Declarations
'Define data tables
DataTable(Temp,1,2000)
DataInterval(0,10,min,10)
Average(1,RefTemp,FP2,0)
Average(6,TC(),FP2,0)
EndTable
Define data table
'Begin Program
BeginProg
'Set scan interval
Scan(1,Sec,3,0)
'Measurements
PanelTemp(RefTemp,250)
TCDiff(TC()...Offset)
Measure
'Processing (None in this
'example)
Scan loop
'Call data table
CallTable Temp
Call data table
'Controls (None in this
'example)
'Loop to next scan
NextScan
'End Program
EndProg
Vista de pagina 113
1 2 ... 109 110 111 112 113 114 115 116 117 118 119 ... 565 566

Comentarios a estos manuales

Sin comentarios