INSTRUCTION MANUAL
10164-L Sampler Control
Cable for use with Isco and
Sigma Autosamplers
Revision: 3/14
Copyright © 1998- 2014
Campbell Scientific, Inc.
Vista de pagina 0
1 2 3 4 5 6 ... 17 18

Indice de contenidos

Pagina 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL 10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers Revision: 3/14 Copyright © 1998-

Pagina 2

10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers TABLE 3-4. Datalogger Wiring to Inhibit a Sigma Sampler Program Color De

Pagina 3 - Limited Warranty

10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers 4.1 CRBasic Programming 4.1.1 Trigger Sampler To trigger the sampler, the dat

Pagina 4 - Assistance

10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers 'CR1000 Series Datalogger 'Declare Public Variables Public Events &

Pagina 5 - Table of Contents

10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers TABLE 4-4. Wiring for Example of Inhibiting a Sigma Sampler Onboard Program Co

Pagina 6

10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers You can also supply the trigger signal from switched excitation if no control p

Pagina 7 - 2. Specifications

10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers 3: Do (P86) 1: 10 Set high Flag 0 (output flag) 4: Set Active Storage

Pagina 8 - 3. Wiring

10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers 10

Pagina 10 - 4. Programming

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Pagina 12

Limited Warranty “Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service

Pagina 13 - 4.2 Edlog Programming

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Pagina 14

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Pagina 15

Table of Contents ii

Pagina 16

10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers 1. General The 10164-L sampler control cable enables a datalogger to trigger

Pagina 17

10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers 3. Wiring 3.1 General Wiring Information FIGURE 3-1 shows a schematic of the

Pagina 18

10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers 3.2 Triggering Sampler TABLE 3-2 shows the datalogger connections required to