Campbell-scientific 034A-L WindSet Manual de usuario Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
MET ONE 034A-L WINDSET
4
TABLE 5-1. Multipliers and Offsets for Wind
Speed and Direction
Units Datalogger
type
Instruction
number
Multiplier
Offset
m s
-1
CR10(X)
or 21X
3 0.7990
0.2811
mph CR10(X)
or 21X
3 1.789
.629
degrees CR10(X)
or 21X
5 720
0
NOTE: 034A-L Windsets purchased
directly from Met One Instruments have a
different configuration on the 6 pin
connector. In addition, they do not have the
10 k resistor on the excitation line. The
wiring diagram and the multiplier and offset,
for wind direction, are different than the
examples in this document.
EXAMPLE 1. Sample CR10(X) Instructions
;{CR10X}
;
*Table 1 Program
01: 10 Execution Interval (seconds)
01: Pulse (P3)
1: 1 Reps
2: 2* Pulse Channel 2
3: 22 Switch Closure, Output Hz
4: 1* Loc [ WndS_m_s ]
5: 0.7990 Mult
6: 0.2811 Offset
;Set the wind speed to zero if the wind is not blowing.
;
02: If (X<=>F) (P89)
1: 1* X Loc [ WndS_m_s ]
2: 1 =
3: 0.2811 F
4: 30 Then Do
03: Z=F (P30)
1: 0 F
2: 0 Exponent of 10
3: 1* Z Loc [ WndS_m_s ]
04: End (P95)
05: AC Half Bridge (P5)
1: 1 Reps
2: 25 ± 2500 mV 60 Hz Rejection Range
3: 5* SE Channel
4: 3* Excite all reps w/Exchan 3
5: 2500 mV Excitation
6: 2* Loc [ WndD_deg ]
7: 720 Mult
8: 0 Offset
06: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 30 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
Vista de pagina 7