Campbell-scientific RTDAQ Software Manual de usuario Pagina 350

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 368
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 349
Section 10. Utilities
TABLE 10-4-1. Transaction Log Messages
Code Message Text Message Parameters Message Meaning User Response to
Message
108 Table reset The name of the table that
was reset; The account
name of the logged in
client
The name of a table
was changed at the
request of a client.
On CR1000,
CR5000, and
CR9000 loggers this
is a reset for the table
in the datalogger and
on the PC.
110 Collect area
setting changed
The name of the collection
area; The setting identifier
for the setting that was
changed; The new value of
the setting; The account
name of the logged in
client.
One of the settings
for the specified
collect area was
changed. The
identifiers for the
setting can be found
in CoraScript help.
111 PakBus route
added
A new PakBus route
has been added to the
routing table.
112 PakBus route
lost
A PakBus route has
been lost and will be
removed from the
routing table.
113 PakBus station
added
A new PakBus
station was added to
the network.
117 Client logged
off
The login name of the
client; The reason the
session was closed.
A client application
has closed or lost the
connection to the
server.
118 Table size
reduced during
creation
The name of the table that
was resized; The original
specified size of the table;
The new size of the table.
The size of the table
in the data cache was
reduced because
there was not enough
computer disk space
to create it, or the file
would have exceeded
the 2 Gbyte size
limit.
Reduce the size of the
tables in the datalogger
program or get more
hard disk storage space
for the computer.
Transaction Log Example
"2009-04-15 16:41:05.367","CR1000","11","Clock check started"
"2009-04-15 16:41:05.429","CR1000","13","Clock checked","2009-04-15 16:41:33.44","2009-04-15 16:41:05.421","-28"
"2009-04-15 16:41:06.367","CR1000","86","Manual poll started","admin"
"2009-04-15 16:41:06.367","CR1000","92","Collect area poll started","TestFast"
"2009-04-15 16:41:06.382","CR1000","41","Records received","TestFast","21007","21007","polling"
"2009-04-15 16:41:06.382","CR1000","20","Hole detected","TestFast","20769","21006"
"2009-04-15 16:41:06.429","CR1000","11","Clock check started"
10-80