Section 19. CsiLogMonitor Control Reference
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
E_CSI_BUSY
Error: The property cannot be set while a connection to
the LoggerNet server is present
LogMonitor.serverLogonPassword
Name
LogMonitor.serverLogonPassword As String
Description
This property specifies the password that should be used when connecting to
the LoggerNet server. If security is enabled on the target LoggerNet server,
this string must be the password associated with the account named by
LogMonitor.serverLogonName.
Default Value
The default value for this property is an empty string. This property will only
affect the operation of the control if security is enabled on the LoggerNet
server.
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
E_CSI_BUSY
Error: The property cannot be set while a connection to the
LoggerNet server is present
LogMonitor.serverName
Name
LogMonitor.serverName As String
Description
This property specifies the TCP/IP interface address for the computer hosting
the LoggerNet server. This string must be formatted either as a qualified
Internet machine domain name or as an Internet address string. An example of
a valid machine domain name address is
www.campbellsci.com. An
example of a valid Internet address string is
63.255.173.183.
Default Value
The default value for this property is the string
localhost.