Campbell-scientific LoggerNet-SDK Software Development Kit Manual de usuario

Busca en linea o descarga Manual de usuario para Software Campbell-scientific LoggerNet-SDK Software Development Kit. Campbell Scientific LoggerNet-SDK Software Development Kit User Manual [es] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 178
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
LoggerNet Software Development Kit
Version 4.1
Programmer’s Reference
Revision: 12/11
Copyright © 2004-2011
Campbell Scientific, Inc.
A
ll rights reserved; no part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form o
r
by any means, electronics, mechanical, photocopying, recording, or otherwise without either the prior written permission o
f
the Publisher. This book may not be lent, resold, hired out or otherwise disposed of by way of trade in any form of binding o
r
cover other than that in which it is published, without the prior written consent of the Publisher. The programs in this manual
have been included for their instructional value. The Publisher does not offer any warranties or representations in respect o
f
their fitness for a particular purpose, nor does the Publisher accept any liability for any loss or damage arising from their use.
Vista de pagina 0
1 2 3 4 5 6 ... 177 178

Indice de contenidos

Pagina 1 - Programmer’s Reference

LoggerNet Software Development KitVersion 4.1Programmer’s ReferenceRevision: 12/11Copyright © 2004-2011Campbell Scientific, Inc.All rights reserved;

Pagina 2

LoggerNet Software Development Kit Table of Contents 13. Developing an Application Using the CsiLogMonitor Control...

Pagina 3 - Agreement (EULA)

Section 17. CsiDatalogger Control Reference Datalogger.loggerName Name Datalogger.loggerName As String Valid Values Specifies the datalogger or stati

Pagina 4

Section 17. CsiDatalogger Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return Datalogger.programS

Pagina 5

Section 17. CsiDatalogger Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return Datalogger.serverLo

Pagina 6

Section 17. CsiDatalogger Control Reference Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: The property cannot

Pagina 7 - Table of Contents

Section 17. CsiDatalogger Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_INVALIDARG Er

Pagina 8

Section 17. CsiDatalogger Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: C

Pagina 9

Section 17. CsiDatalogger Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return Datalogger.loggerCo

Pagina 10

Section 17. CsiDatalogger Control Reference Datalogger.manualPollCancel() Name Datalogger.manualPollCancel() Description This method should be calle

Pagina 11 - Appendix

Section 17. CsiDatalogger Control Reference Datalogger.programReceiveCancel() Name Datalogger.programReceiveCancel() Description This method attempts

Pagina 12 - Figures

Section 17. CsiDatalogger Control Reference Datalogger.programSendCancel() Name Datalogger.programSendCancel() Description This method attempts to c

Pagina 13 - 1.2 Requirements

LoggerNet Software Development Kit Table of Contents 18. CsiDataSource Control Reference ...18-1 18.1 DSource Interface ...

Pagina 14 - 1.3 Included Components

Section 17. CsiDatalogger Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: A

Pagina 15 - Control…

Section 17. CsiDatalogger Control Reference Datalogger.serverConnect() Name Datalogger.serverConnect() Description This method attempts to connect t

Pagina 16

Section 17. CsiDatalogger Control Reference Parameters successful: Describes whether a clock set or clock check succeeded. response_code: The follow

Pagina 17

Section 17. CsiDatalogger Control Reference Enumeration Name Value Description co_outcome_invalid_device_name 9 Indicates that the device named b

Pagina 18 - 2.2.3 Events

Section 17. CsiDatalogger Control Reference Enumeration Name Value Description lf_failure_invalid_logon 3 Indicates that this control was unable

Pagina 19 - 3.1 Purpose

Section 17. CsiDatalogger Control Reference Datalogger_onManualPollComplete() Name onManualPollComplete(Boolean successful, manual_poll_outcome_type

Pagina 20

Section 17. CsiDatalogger Control Reference Enumeration Name Value Description mp_outcome_communication_disabled 9 Indicates that LoggerNet has b

Pagina 21

Section 17. CsiDatalogger Control Reference Datalogger_onProgramReceiveComplete() Name onProgramReceiveComplete(Boolean successful, prog_receive_outc

Pagina 22

Section 17. CsiDatalogger Control Reference Enumeration Name Value Description pr_failure_cannot_open_file 9 Indicates that the file could not be

Pagina 23

Section 17. CsiDatalogger Control Reference Parameters successful: Describes if the programSendStart was successful. response_code: Found in the tabl

Pagina 24 - 4.3.1 Setting up a Network

LoggerNet Software Development Kit Table of Contents vi A.2.16 Values to Collect ...

Pagina 25

Section 17. CsiDatalogger Control Reference Enumeration Name Value Description ps_outcome_cannot_open_file 12 Indicates that the program to send

Pagina 26 - 4.4 CsiCoraScript Interface

Section 17. CsiDatalogger Control Reference Datalogger_onProgramSent() Name onProgramSent() Description This event returns notification when the prog

Pagina 27 - 5.1 Purpose

Section 17. CsiDatalogger Control Reference Enumeration Name Value Description smp_outcome_server_security_blocked 6 Indicates that the account sp

Pagina 28

Section 17. CsiDatalogger Control Reference Enumeration Name Value Description server_failure_session 2 Indicates that the communication session

Pagina 29

Section 17. CsiDatalogger Control Reference 17-26

Pagina 30

Section 18. CsiDataSource Control Reference 18.1 DSource Interface 18.1.1 Properties DSource.logonName Name DSource.logonName As String Descriptio

Pagina 31

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return. E_CSI_BUSY Error:

Pagina 32 - 6.3 How Collections Work

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return. E_CSI_BUSY Error:

Pagina 33 - 6.4.1 BrokerMap Interface

Section 18. CsiDataSource Control Reference Default Value This property is set to FALSE by default. COM Return Values Table of Possible Values Code M

Pagina 34 - 6.4.5 Table Interface

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_NOT_CONNECTED

Pagina 35 - 6.4.7 Column Interface

Section 1. LoggerNet SDK Overview 1.1 Purpose of the LoggerNet SDK The LoggerNet Software Development Kit (SDK) provides a method to communicate wit

Pagina 36

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return DSource_onAdviseRec

Pagina 37 - 7.1 Purpose

Section 18. CsiDataSource Control Reference Enumeration Name Value Description csiAdvisorFailureInvalidLogon 2 Indicates that this control was unab

Pagina 38

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return DSource_onControlFa

Pagina 39

Section 18. CsiDataSource Control Reference DSource_onControlReady() Name onControlReady() Description This event is triggered when a connection to

Pagina 40

Section 18. CsiDataSource Control Reference Enumeration Name Value Description vo_outcome_column_read_only 5 Indicates that the column sent is read

Pagina 41 - Section 8. CsiDatalogger

Section 18. CsiDataSource Control Reference Description This event notification returns a block of records delivered by LoggerNet to an active adviso

Pagina 42 - 8.3.3 Events

Section 18. CsiDataSource Control Reference Enumeration Name Value Description csidsOrderLoggedWithHoles 2 The records will be sent in the order t

Pagina 43 - Using the Datalogger Control

Section 18. CsiDataSource Control Reference Notes This property can be read at any time but can only be set when the state of the property is advisor

Pagina 44

Section 18. CsiDataSource Control Reference Advisor.startIntervalSeconds Name Advisor.startIntervalSeconds As Long Description This property specifie

Pagina 45

Section 18. CsiDataSource Control Reference Table of possible csidsStartOptionType values Enumeration Name Value Description csidsStartAtRecordId

Pagina 46

Section 1. LoggerNet SDK Overview The C#.NET and VB.NET example code targets the x86 compilation platform to facilitate proper functionality on 64-bi

Pagina 47 - End Sub

Section 18. CsiDataSource Control Reference Advisor.startRecordNo Name Advisor.startRecordNo As Long Description This property, in conjunction with

Pagina 48

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: T

Pagina 49

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: T

Pagina 50

Section 18. CsiDataSource Control Reference Advisor.maxRecordsPerBlock Name Advisor.maxRecordsPerBlock As Long Description This property sets the max

Pagina 51

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_ALREADY_CONNEC

Pagina 52 - 10.3.2 Advisor Interface

Section 18. CsiDataSource Control Reference Advisor.variableSetStart() Name Advisor.variableSetStart(String column_name, String value) As Long Descr

Pagina 53 - 10.3.4 DataColumn Interface

Section 18. CsiDataSource Control Reference 18.3 DataColumnCollection Interface 18.3.1 Properties DataColumnCollection.count Name DataColumnCollect

Pagina 54 - 10.3.7 Value Interface

Section 18. CsiDataSource Control Reference DataColumnCollection.addAll() Name DataColumnCollection.addAll() Description This method adds all of the

Pagina 55 - 11.1 Purpose

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_INVALIDARG Er

Pagina 56

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return DataColumnCollecti

Pagina 57

Section 1. LoggerNet SDK Overview 1.3.2 Adding Controls to a Project This section describes how to add controls to a project in Visual Basic 6.0, De

Pagina 58

Section 18. CsiDataSource Control Reference unique key for each record. This property can take on any value from 0 to 2147483647. COM Return Values

Pagina 59

Section 18. CsiDataSource Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return Record.valuesCount

Pagina 60 - 12.2.3 Events

Section 18. CsiDataSource Control Reference 18.5.2 Methods Record.Item() Name Record.Item(id) As Value Description This method returns a reference

Pagina 61 - 13.1 Purpose

Section 18. CsiDataSource Control Reference Important This method is only intended for use with the Visual Basic programming language. Visual Basic

Pagina 62

Section 18. CsiDataSource Control Reference 18-30 RecordCollection._NewEnum() Name RecordCollection._NewEnum() Important This method is not accessed

Pagina 63

Section 19. CsiLogMonitor Control Reference 19.1 LogMonitor Interface 19.1.1 Properties LogMonitor.commLogMonitorBusy Name LogMonitor.commLogMonito

Pagina 64

Section 19. CsiLogMonitor Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_INVALIDARG Er

Pagina 65

Section 19. CsiLogMonitor Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: T

Pagina 66

Section 19. CsiLogMonitor Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: At

Pagina 67

Section 19. CsiLogMonitor Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return LogMonitor.tranLog

Pagina 68 - 14.1.2 Methods

Section 1. LoggerNet SDK Overview 5. A confirmation message similar to one below will appear. Click on Yes. 6. A new window titled Information (n

Pagina 69 - 14.1.3 Events

Section 19. CsiLogMonitor Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_FAIL Error: U

Pagina 70

Section 19. CsiLogMonitor Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_FAIL Error: U

Pagina 71

Section 19. CsiLogMonitor Control Reference LogMonitor.tranLogMonitorStop() Name LogMonitor.tranLogMonitorStop() Description This method will stop a

Pagina 72

Section 19. CsiLogMonitor Control Reference Table of Possible failure codes. Enumeration Name Value Description lm_failure_unknown 0 Indicates t

Pagina 73 - 15.1.2 Methods

Section 19. CsiLogMonitor Control Reference Description This event indicates there was an error with the connection to the LoggerNet server. This ev

Pagina 74 - 15.1.3 Events

Section 19. CsiLogMonitor Control Reference Description This event indicates an error has occurred while trying to retrieve transaction log entries f

Pagina 75

Section 19. CsiLogMonitor Control Reference 19-12

Pagina 76

Appendix A. Server and Device Operational Statistics Tables The LoggerNet server and devices in the network map maintain statistics that help to desc

Pagina 77

Appendix A. Server and Device Operational Statistics Tables Description: Records the total number of retires that the device experienced during the te

Pagina 78

Appendix A. Server and Device Operational Statistics Tables Applies To: All Device Types Description: A running total of the number of communication

Pagina 79

Section 2. CsiServerDirect Control 2.1 Purpose of the CsiServerDirect Control The CsiServerDirect Control allows the user to start and stop the incl

Pagina 80 - 16.1.2 Methods

Appendix A. Server and Device Operational Statistics Tables A.2.10 Collection Enabled Column Name: “Collection Enabled” Column Definition Description

Pagina 81 - 16.1.3 Events

Appendix A. Server and Device Operational Statistics Tables Applies To: 21X, CR7X, CR10, CR10X, CR500, CR510, CR23X, CR10T, CR10X-TD, CR510-TD, CR23X

Pagina 82

Appendix A. Server and Device Operational Statistics Tables PB, CR23X-TP, CR205, CR210, CR215, CR1000, CR3000, CR800, and CR850. Description: The numb

Pagina 83 - 16.2.1 Properties

Appendix A. Server and Device Operational Statistics Tables Description: Reflects whether there is presently a polling operation that is active for t

Pagina 84 - 16.2.2 Methods

Appendix A. Server and Device Operational Statistics Tables A.2.26 Watchdog Err Column Name: “Watchdog_Timer_Reset Count” Column Definition Descripti

Pagina 85 - 16.3 Broker Interface

Appendix A. Server and Device Operational Statistics Tables A.2.31 Low Five Volts Error Count Column Name: “Low_5v” Column Definition Description: “

Pagina 86

Appendix A. Server and Device Operational Statistics Tables A-10 A.3.1 Disc Space Available Column Name: “DiscSpaceAvail” Column Definition Descripti

Pagina 88 - 16.4.2 Methods

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Pagina 89

Section 2. CsiServerDirect Control 2-2 2.2.1 Properties • applicationWorkDir As String • buildDate As String (read-only) • logFileDir As String •

Pagina 90 - 16.5 Table Interface

Section 3. Developing an Application Using the CsiServerDirect Control 3.1 Purpose This section shows by example how to build an application using t

Pagina 92 - 16.6.2 Methods

Section 3. Developing an Application Using the CsiServerDirect Control CsiLogMonitor 1.0 Type Library CsiServerDirect 1.0 Type Library Check the box

Pagina 93

Section 3. Developing an Application Using the CsiServerDirect Control In order to stop the limited LoggerNet server, use the method stopServer(). A

Pagina 94 - 16.7 Column Interface

Section 3. Developing an Application Using the CsiServerDirect Control 3-4

Pagina 95

Section 4. CsiCoraScript Control 4.1 Purpose of the CsiCoraScript Control The CsiCoraScript control provides the power to administer the LoggerNet s

Pagina 96

Section 4. CsiCoraScript Control 4.3.1 Setting up a Network Some of the commands that can be used when initially setting up a datalogger network on

Pagina 97

Section 4. CsiCoraScript Control 4.3.2.1 Table-Data Dataloggers The LoggerNet server, by default, creates a collect area for the Public or InLocs ta

Pagina 98

Section 4. CsiCoraScript Control 4-4 Collect area names must always be unique. Therefore, if an attempt is made to create a collect area with exactl

Pagina 99

Section 5. Developing an Application Using the CsiCoraScript Control 5.1 Purpose This section shows an example of how to build an application using

Pagina 100

Section 5. Developing an Application Using the CsiCoraScript Control Check the box next to the CsiCoraScript 1.0 Type Library, click Apply, and then

Pagina 101

Section 5. Developing an Application Using the CsiCoraScript Control Private Sub cmdConnect_Click() 'Connect using the default logon settings. C

Pagina 102

Campbell Scientific, Inc. Software SDK End User License Agreement (EULA) NOTICE OF AGREEMENT: Please carefully read this EULA. By installing or using

Pagina 103

Section 5. Developing an Application Using the CsiCoraScript Control 5-4

Pagina 104 - 17.1.2 Methods

Section 6. CsiBrokerMap Control 6.1 Purpose of the CsiBrokerMap Control The CsiBrokerMap control gives developers access to the broker map, which is

Pagina 105

Section 6. CsiBrokerMap Control 6.3 How Collections Work The CsiBrokerMap uses the concept of collections in its implementation. Collections provide

Pagina 106

Section 6. CsiBrokerMap Control 6.4 CsiBrokerMap Interfaces The following interfaces are included in the CsiBrokerMap control: • Broker • Broker

Pagina 107 - E_CSI_NOT_CONNECTED

Section 6. CsiBrokerMap Control 6.4.2.2 Methods • item(id) As Broker • _NewEnum() (GetEnumerator() in .NET) 6.4.3 Broker Interface See the Refer

Pagina 108

Section 6. CsiBrokerMap Control 6.4.6 ColumnCollection Interface See the Reference Section for descriptions of these properties and methods. 6.4.6.

Pagina 109

Section 6. CsiBrokerMap Control 6-6

Pagina 110

Section 7. Developing an Application Using the CsiBrokerMap Control 7.1 Purpose This section shows by example how to build an application using the

Pagina 111 - 17.1.3 Events

Section 7. Developing an Application Using the CsiBrokerMap Control 2. Start a new project (File | New Project | Standard EXE | OK). This will open

Pagina 112

Section 7. Developing an Application Using the CsiBrokerMap Control Now that the interface has been designed, the code can be organized to accomplish

Pagina 113

7) If the software program you develop requires you, your customer, or a third party to use additional licensable software from Campbell Scientific,

Pagina 114

Section 7. Developing an Application Using the CsiBrokerMap Control 7-4 "." & t.Name & "." & c.Name, c.Name)

Pagina 115

Section 8. CsiDatalogger 8.1 Purpose of the CsiDatalogger Control The CsiDatalogger control allows the developer to manage datalogger functions thro

Pagina 116

Section 8. CsiDatalogger 8-2 8.3.2 Methods • clockCancel() • clockCheckStart() • clockSetStart() • loggerConnectCancel() • loggerConnectStart(l

Pagina 117

Section 9. Developing an Application Using the Datalogger Control 9.1 Purpose This section illustrates the use of the CsiDatalogger control. This c

Pagina 118

Section 9. Developing an Application Using the Datalogger Control 2. Start a new project (File | New Project | Standard EXE | OK). This will open a

Pagina 119

Section 9. Developing an Application Using the Datalogger Control Now that the interface has been designed, the code can be organized to accomplish t

Pagina 120

Section 9. Developing an Application Using the Datalogger Control Private Sub cmdDataloggerConnect_Click() 'Create an active connection to the

Pagina 121

Section 9. Developing an Application Using the Datalogger Control Private Sub cmdCheck_Click() 'Check the clock on the datalogger. If DataLo

Pagina 122

Section 9. Developing an Application Using the Datalogger Control Private Sub cmdDataStart_Click() 'Begin a manual poll to retrieve data If

Pagina 123

Section 9. Developing an Application Using the Datalogger Control Private Sub cmdRetrieve_Click() 'Get the current program from the datalogger

Pagina 124

application. This information should appear on the first window the user will see. WARRANTIES: The following warranties are in effect for ninety (90)

Pagina 125 - Reference

Section 9. Developing an Application Using the Datalogger Control 9-8

Pagina 126 - 207.201.118.35

Section 10. CsiDataSource Control 10.1 Purpose of the CsiDataSource Control The CsiDataSource control allows an application to monitor data collecte

Pagina 127

Section 10. CsiDataSource Control 10.3 CsiDataSource Interfaces The following interfaces are used in the CsiDataSource control: • DSource – the con

Pagina 128 - 18.1.2 Methods

Section 10. CsiDataSource Control 10.3.2.1 Properties • advisorName As String • orderOption As csidsOrderOptionType • startDate As Date • startF

Pagina 129 - 18.1.3 Events

Section 10. CsiDataSource Control 10-4 10.3.5 Record See the Reference Section for descriptions of these properties, methods, and events. 10.3.5.1

Pagina 130

Section 11. Developing an Application Using the CsiDataSource Control 11.1 Purpose The CsiDataSource control primarily monitors data residing in the

Pagina 131

Section 11. Developing an Application Using the CsiDataSource Control 3. View the toolbox for this new project (VB 6 Main Menu | View | Toolbox). 4

Pagina 132

Section 11. Developing an Application Using the CsiDataSource Control Now that the interface has been designed, the code can be organized to accompli

Pagina 133

Section 11. Developing an Application Using the CsiDataSource Control 11-4 Private Sub DSource_onAdviseRecord(ByVal myAdvisor As Object, _ ByVal myRe

Pagina 134

Section 12. CsiLogMonitor Control 12.1 Purpose of the CsiLogMonitor Control The CsiLogMonitor Control provides access to log message from the Logger

Pagina 135 - 18.2 Advisor Interface

There is no written or implied warranty provided with the LoggerNet SDK software other than as stated herein. Developer agrees to bear all warranty r

Pagina 136

Section 12. CsiLogMonitor Control 12-2 12.2 CsiLogMonitor Interface See the Reference section in this manual for detailed descriptions of these prop

Pagina 137

Section 13. Developing an Application Using the CsiLogMonitor Control 13.1 Purpose This section shows an example of how to build an application usin

Pagina 138

Section 13. Developing an Application Using the CsiLogMonitor Control Check the box next to the CsiLogMonitor 1.0 Type Library, click Apply, and clos

Pagina 139

Section 13. Developing an Application Using the CsiLogMonitor Control Private Sub cmdConnect_Click() 'Connect using the default logon settings.

Pagina 140

Section 13. Developing an Application Using the CsiLogMonitor Control 13-4 Stop monitoring logs with the commLogMonitorStop() and tranLogMonitorStop(

Pagina 141

Section 14. CsiServerDirect Control Reference 14.1 ServerDirect Interface 14.1.1 Properties ServerDirect.applicationWorkDir Name ServerDirect.appli

Pagina 142

Section 14. CsiServerDirect Control Reference ServerDirect.logFileDir Name ServerDirect.logFileDir As String Description This property specifies the

Pagina 143 - 18.2.2 Methods

Section 14. CsiServerDirect Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_FAIL Error:

Pagina 144

Section 14. CsiServerDirect Control Reference ServerDirect.tcpPortEx Name ServerDirect.tcpPortEx As Long Description This property sets the TCP port

Pagina 145

Section 14. CsiServerDirect Control Reference ServerDirect.stopServer() Name ServerDirect.stopServer() Description This method will stop the limited

Pagina 146 - 18.3.2 Methods

LoggerNet Software Development Kit Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adob

Pagina 147

Section 14. CsiServerDirect Control Reference 14-6

Pagina 148

Section 15. CsiCoraScript Control Reference 15.1 CoraScript Interface 15.1.1 Properties CoraScript.serverConnected Name CoraScript.serverConnected

Pagina 149 - 18.5 Record Interface

Section 15. CsiCoraScript Control Reference CoraScript.serverLogonPassword Name CoraScript.serverLogonPassword As String Valid Values If security is

Pagina 150

Section 15. CsiCoraScript Control Reference CoraScript.serverPort Name CoraScript.serverPort As Long Description Specifies the TCP port number that

Pagina 151

Section 15. CsiCoraScript Control Reference CoraScript.serverConnect() Name CoraScript.serverConnect() Description This method attempts to connect t

Pagina 152 - 18.5.2 Methods

Section 15. CsiCoraScript Control Reference CoraScript_onServerConnectStarted() Name onServerConnectStarted() Description The control has connected t

Pagina 153 - 18.6 RecordCollection

Section 15. CsiCoraScript Control Reference 15-6

Pagina 154 - 18.7 Value Interface

Section 16. CsiBrokerMap Control Reference 16.1 BrokerMap Interface 16.1.1 Properties BrokerMap.serverName Name BrokerMap.serverName As String Desc

Pagina 155

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: At

Pagina 156

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_BUSY Error: At

Pagina 157 - 63.255.173.183

LoggerNet Software Development Kit Table of Contents 5. Developing an Application Using the CsiCoraScript Control ...

Pagina 158

Section 16. CsiBrokerMap Control Reference 16.1.2 Methods BrokerMap.Brokers() Name BrokerMap.Brokers() As Object Description Use this method to iter

Pagina 159 - 19.1.2 Methods

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_ALREADY_CONNECT

Pagina 160

Section 16. CsiBrokerMap Control Reference BrokerMap_onFailure() Name onFailure(BrokerMapFailureType failure_code) Description When the BrokerMap co

Pagina 161

Section 16. CsiBrokerMap Control Reference BrokerMap.onTableDeleted() Name BrokerMap_onTableDeleted(Object Broker, Object Table) Description This ev

Pagina 162 - 19.1.3 Events

Section 16. CsiBrokerMap Control Reference 16.2.2 Methods BrokerCollection.Item() Name BrokerCollection.Item(id) As Broker Description A Broker can

Pagina 163

Section 16. CsiBrokerMap Control Reference BrokerCollection._NewEnum() Name BrokerCollection._NewEnum() — Return the next broker in the broker map se

Pagina 164

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return. Broker.type Name B

Pagina 165

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return Broker.allStarted Na

Pagina 166

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return 16.4 TableCollectio

Pagina 167 - A.1.3 Retries

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_ARRAY_OUT_OF_BO

Pagina 168 - A.2.5 Total Attempts

LoggerNet Software Development Kit Table of Contents 8.3 Datalogger Interface ...

Pagina 169 - A.2.9 Last Clock Difference

Section 16. CsiBrokerMap Control Reference 16.5 Table Interface 16.5.1 Properties Table.interval Name Table.interval As Long Description The time

Pagina 170 - A.2.14 Collection State

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return Table.size Name Tabl

Pagina 171 - A.2.17 Values in Holes

Section 16. CsiBrokerMap Control Reference Table.start_expansion Name Table.start_expansion() Description If the BrokerMap autoExpand property has be

Pagina 172 - A.2.20 Polling Active

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return E_CSI_ARRAY_OUT_OF_BO

Pagina 173 - A.2.25 Logger Ver

Section 16. CsiBrokerMap Control Reference 16.7 Column Interface 16.7.1 Properties Column.description Name Column.description As String Description

Pagina 174 - A.2.29 Collect Retries

Section 16. CsiBrokerMap Control Reference COM Return Values Table of Possible Values Code Meaning S_OK Success: Normal return Column.type Name Col

Pagina 175 - A.3 Server Statistics

Section 16. CsiBrokerMap Control Reference Name Value Description dt_CsiAscii 11 fixed-length string dt_CsiAsciiZ 16 null-terminated variabl

Pagina 176 - A.3.3 Used Virtual Memory

Section 16. CsiBrokerMap Control Reference Column.writable Name Column.writable As Long Description This property is read-only and describes whether

Pagina 177

Section 16. CsiBrokerMap Control Reference 16-22

Pagina 178

Section 17. CsiDatalogger Control Reference 17.1 Datalogger Interface 17.1.1 Properties Datalogger.clockBusy Name Datalogger.clockBusy As Boolean

Comentarios a estos manuales

Sin comentarios