Section 17. CsiDatalogger Control Reference
Datalogger.manualPollCancel()
Name
Datalogger.manualPollCancel()
Description
This method should be called to cancel a manualPollStart() command. If the
manual poll was successfully cancelled, then the event
onManualPollComplete(), will return a cancellation code. If the
manualPollCancel() was called too late in the manual poll process, then the
event onManualPollComplete(), will return either a success or failure code
instead. This method should only be called when a manual poll is in process.
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
Datalogger.manualPollStart()
Name
Datalogger.manualPollStart()
Description
This method should be called when the client desires to perform a manual poll
of the specified datalogger. This method should only be called when the value
of serverConnected, is TRUE. If not, this method will return
E_CSI_NOT_CONNECTED. Upon completion, this method calls the event
onManualPollComplete().
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
E_CSI_BUSY
Error: Manual poll communication is busy
servicing a request
E_CSI_FAIL
Error: Unexpected error
E_CSI_NOT_CONNECTED