RAWS-P Remote Automated Weather Station
FIGURE 5-2. GOES transmitter
5.4.2 Wiring
The TX320 is mounted inside the RAWS environmental enclosure and the
transmitter connections are described below.
TABLE 5-1. GOES Transmitter Connections
TX320 Connector Connects to
CS I/O CR1000 CS I/O port via SC12 cable (shipped with the
RAWS-P)
GPS GPS antenna cable
RF Out GOES antenna cable
Green Power Port Battery Cable Junction Connector