NR-LITE2 Net Radiometer
VoltDiff(NR_Wm2,1,mv25,2,True,0,_60Hz,100,0)
If WS_ms>=5 Then
CNR_Wm2=NR_Wm2*(1+0.021286*(WS_ms-5))
Else
CNR_Wm2=NR_Wm2
EndIf
'Call Data Tables and Store Data
CallTable(Table1)
CallTable(Table2)
NextScan
EndProg
7.2.3.3 CR10(X) Example Program without Wind Speed Correction
Shown below is an example program written for the CR10(X) datalogger.
TABLE 7-5 provides the wiring for the example program. In this example, the
datalogger measures the output from the sensor every 60 seconds and outputs
the average net radiation every hour.
The calibration factor used will only apply for one specific sensor. A new
value will need to be calculated for every different sensor based on the
Certificate of Calibration for that sensor (Section 7.2.2, Calibration Factor).
TABLE 7-5. Wiring for CR10X Example
(without Wind Correction)
Color Function CR10X Channels
Red Radiation Signal 1H
Blue Signal Reference 1L
Jumpered to AG
Black Shield G
;{CR10X}
;
*Table 1 Program
01: 60 Execution Interval (seconds)
1: Volt (DIFF) (P2)
1: 1 Reps
2: 3** 25 mV Slow Range ;range code for CR10(X) datalogger
3: 1* DIFF Channel
4: 1* Loc [ Net_rad ]
5: 63.29 Mult ;Multiplier for specific sensor
6: 0.0 Offset ;in units of (W m
-2
)/mV (see above)
2: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
3: Real Time (P77)
1: 110 Day,Hour/Minute (midnight = 0000)
4: Average (P71)
1: 1 Reps
2: 1 Loc [ Net_rad ]
17