Campbell-scientific CS105/CS105MD Barometric Pressure Sensor Manual de usuario

Busca en linea o descarga Manual de usuario para Sensores Campbell-scientific CS105/CS105MD Barometric Pressure Sensor. Campbell Scientific CS105/CS105MD Barometric Pressure Sensor User Manual [en] [es] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
CS105/CS105M
D
Barometric Pressure Senso
r
Revision: 3/07
Copyright © 1995-2007
Campbell Scientific, Inc.
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1 - Barometric Pressure Senso

CS105/CS105MDBarometric Pressure SensorRevision: 3/07Copyright © 1995-2007Campbell Scientific, Inc.

Pagina 2 - Warranty and Assistance

CS105/CS105MD Barometric Pressure Sensor 4. Programming 4.1 CS105MD Programming the MetData1 station for the CS105MD is done through Campbell Scient

Pagina 3

CS105/CS105MD Barometric Pressure Sensor Example 1. CR1000 Program for Measuring the CS105 Once Every Hour 'Main Program BeginProg Scan(5,Sec,1

Pagina 4

CS105/CS105MD Barometric Pressure Sensor 07: Real Time (P77) 1: 0110 Day,Hour/Minute 08: Sample (P70) 1: 1 Reps 2: 1* Loc [ P_mb ]

Pagina 5 - 1. General

CS105/CS105MD Barometric Pressure Sensor -Input Locations- 1 P_mb * Proper entries will vary with program and datalogger channel, and input locatio

Pagina 6 - 3. Installation and Wiring

CS105/CS105MD Barometric Pressure Sensor Example 5. CR10(X) Program for Measuring the CS105 Once Every Hour with Instruction 2 (Differential Measurem

Pagina 7 - MADE IN FINLAND

CS105/CS105MD Barometric Pressure Sensor 6. Correcting Pressure to Sea Level The weather service, most airports, radio stations, and television stati

Pagina 8 - PRESSURE TRANSMITTER

CS105/CS105MD Barometric Pressure Sensor This is a blank page. 12

Pagina 9

Appendix A. Daily Average If the CS105 will be measured every minute or faster, and a daily average is required, follow Example 5. In Example 5 the

Pagina 10 - 4. Programming

Appendix A. Daily Average 08: Average (P71) 1: 1 Reps 2: 2* Loc [ P_const ] 09: If Flag/Port (P91) 1: 10 Do if Output Flag is Hig

Pagina 11

This is a blank page.

Pagina 12

Warranty and Assistance The CS105/CS105MD BAROMETRIC PRESSURE SENSOR is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials an

Pagina 13 - 5. Long Lead Lengths

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbells

Pagina 14

CS105/CS105MD Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks

Pagina 15 - 7. Maintenance

This is a blank page.

Pagina 16 - This is a blank page

CS105/CS105MD Barometric Pressure Sensor 1. General The CS105 analog barometer uses Vaisala’s Barocap® silicon capacitive pressure sensor. The Baroc

Pagina 17 - Appendix A. Daily Average

CS105/CS105MD Barometric Pressure Sensor Supply Voltage: 10 to 30 VDC Supply Voltage Control: When enabled with an internal jumper, the CS105 is on

Pagina 18

CS105/CS105MD Barometric Pressure Sensor FIGURE 1. CS105 Mounted on the Backplate of an ENC12/14 Enclosure, and Connected to a CR1000 Datalogger INT

Pagina 19

CS105/CS105MD Barometric Pressure Sensor VAISALAEXT. TRIGAGNDGNDSUPPLYVOUTPRESSURE TRANSMITTERMODELSERIAL NORANGEOUTPUTSUPPLYPTB101BP4450003600-1060 h

Pagina 20

CS105/CS105MD Barometric Pressure Sensor VAISALAEXT. TRIGAGNDGNDSUPPLYVOUTPRESSURE TRANSMITTERMODELSERIAL NORANGEOUTPUTSUPPLYPTB101BP4450003600-1060 h

Comentarios a estos manuales