CVS4200 / BVS4300 Stationary Samplers
3. Flow-Through Chamber. Divert liquid from the pressurized line to a
“wet well” or secondary pool, and attach this component to it, as shown in
FIGURE 5-9.
4. Configuring a Combination of Valves. Using a combination of valves,
such as pressure reducing valves and ball valves, previous customers have
successfully managed to take samples under a certain amount of pressure
without flooding the system.
FLOW-THROUGH CHAMBER
MUST BE INSTALLED BELOW
ELEVATION OF METERING
CHAMBER TO AVOID
FLOODING OF SAMPLER.
FIGURE 5-9. Flow-through chamber for pressurized source
19