APPENDIX B. CONTROL PORT SERIAL I/O INSTRUCTION 15
B-13
02: P89 If X<=>F START: Limit testing
01: 1 X Loc AIR, mb
02: 3 >= If reading is > 1300 mb
03: 1300 F
04: 11 Set high Flag 1 then set Flag 1 high
03: P89 If X<=>F
01: 1 X Loc AIR, mb
02: 4 < If reading is < 800 mb
03: 800 F
04: 11 Set high Flag 1 then set Flag 1
04: P91 If Flag/Port If Flag 1 is set,
01: 11 Do if flag 1 is high
02: 30 Then Do do the following.
05: P86 Do Output time of failure
01: 10 Set high Flag 0 (output)
06: P77 Real Time
01: 110 Day,Hour-Minute
07: P70 Sample Output out of range reading
01: 1 Rep
02: 1 Loc AIR, mb
08: P86 Do Set Intermediate Processing
01: 19 Set high Flag 9 Disable Flag
09: P86 Do Set Flag 1 low
01: 21 Set low Flag 1
10: P95 End End of If Flag Then Do
11: P92 If time is Output mb twice/day
01: 0 minutes into a
02: 720 minute interval
03: 10 Set high Flag 0 (output)
12: P77 Real Time
01: 110 Day,Hour-Minute
13: P71 Average
01: 1 Reps
02: 1 Loc AIR, mb
14: P End Table 1
Input Location Labels:
1:AIR, mb