27106T Gill Propeller Anemometer
'Define Data Tables
DataTable (Table1,True,-1)
DataInterval (0,10,Min,10)
Maximum (1,WS_ms,FP2,False,False)
Minimum (1,WS_ms,FP2,0,False)
Average (1,WS_ms,FP2,False)
EndTable
'Main Program
BeginProg
Scan (1,Sec,1,0)
Battery (Batt_Volt)
'27106T Wind Speed Sensor measurement
VoltSe (WS_ms,1,mV2500,1,1,0,250,0.01800,0)
'mV5000 range code for CR3000 and CR5000 dataloggers
'Call Output Tables
CallTable Table1
NextScan
EndProg
5.2.2 CR10X Example Program
;{CR10X}
;
*Table 1 Program
01: 1.000 Execution Interval (seconds)
;27106T Wind Speed Sensor Measurement
1: Volt (SE) (P1)
1: 1 Reps
2: 5 2500 mV Slow Range ;5000mV (slow 60Hz) Range for CR23X, 21X, CR7
3: 1 SE Channel
4: 1 Loc [ WS_ms ]
5: 0.01800 Multiplier
6: 0 Offset
2: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 10 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
3: Set Active Storage Area (P80)^23620
1: 1 Final Storage Area 1
2: 101 Array ID
4: Real Time (P77)^28329
1: 1220 Year,Day,Hour/Minute (midnight = 2400)
5: Maximum (P73)
1: 1 Reps
2: 0 Value Only
3: 1 Loc [ WS_ms ]
7
Vista de pagina 10