Appendix E. NL100 to MD485 Network
FIGURE E-3. LoggerNet NL100 to MD485 PakBus Networking Setup
MD485 Configuration
5) Active Ports – “CS I/O and RS-485”
6) Communication Mode – “PakBus Networking”
7) CS I/O Port Configuration – SDC7 or SDC8
8) RS-485 Port Configuration – Desired baud rate
NL100 Configuration
7) RS-485 config – “PakBus”
8) RS-485 bps – Desired baud rate
9) RS-485 beacon interval – 60
10) Ethernet 10aseT – “enabled”
11) 10BaseT port IP address – NL100 IP address
12) 10aseT port network mask– NL100 network mask
13) PakBus/TCP server config – “enabled”
14) PakBus/TCP server port number – May be left at default, but must
match what is entered in LoggerNet Setup
The other NL100 options can be left in their default state.
E-5