Campbell-scientific MD485 RS-485 Multidrop Interface Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware Campbell-scientific MD485 RS-485 Multidrop Interface. Campbell Scientific MD485 RS-485 Multidrop Interface User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Multidrop Interface

MD485 RS-485Multidrop InterfaceRevision: 10/10Copyright © 2003-2010Campbell Scientific, Inc.

Pagina 2 - Warranty and Assistance

MD485 RS-485 Multidrop Interface The baud rate for each port is set independently, so they can be different. However, in some instances, mismatched

Pagina 3 - MD485 Table of Contents

MD485 RS-485 Multidrop Interface (-)(+)(-) (+) Connect at oneend only to chassis GND. FIGURE 3. RS-485 Connections and Grounding 3.4 Serial Cables

Pagina 4

MD485 RS-485 Multidrop Interface Step 1 – Set Up Base MD485 a. Connect serial cable from PC COM port to base MD485 RS-232 port. b. Plug transformer

Pagina 5

MD485 RS-485 Multidrop Interface Current dataloggers and wiring panels (not mentioned in Table 2) provide 12 V on pin 8. For older products not lis

Pagina 6

MD485 RS-485 Multidrop Interface b. Set the Maximum Baud Rate for 9600 baud which is the rate at which the MD485 communicates by default. The datalo

Pagina 7 - 2. Specifications

MD485 RS-485 Multidrop Interface The base MD485 is connected to the computer's COM port with a serial cable. A transformer supplies +12 VDC powe

Pagina 8 - 3. System Components

MD485 RS-485 Multidrop Interface active ports, while the remote MD485 has the active ports set to RS-485 and CS I/O. With the MD485s configured as tr

Pagina 9 - 3.1.3 Configuring the MD485

MD485 RS-485 Multidrop Interface SCADA-PC SCADA-PC MODBUSTo Wall Transformer FIGURE 10. Transparent Point-to-Multipoint Network 5.2 MD9 Emula

Pagina 10 - 3.3 RS-485 Cable

MD485 RS-485 Multidrop Interface 5.3 PakBus Networking When configured to use PakBus protocol, the MD485 makes use of the PakBus/Mdrop protocol on th

Pagina 11 - 4. Quick Start

MD485 RS-485 Multidrop Interface 7. Call-back Datalogger initiated communication, commonly referred to as “call-back,” is possible through MD485s in

Pagina 12 - Step 2 – Set Up Remote MD485

Warranty and Assistance The MD485 RS-485 MULTIDROP INTERFACE is warranted by Campbell Scientific, Inc. to be free from defects in materials and workma

Pagina 13

MD485 RS-485 Multidrop Interface The RS-485 specification also recommends connecting a 100 ohm resistor of at least 0.5 W in series between each node’

Pagina 14 - 5. System Configuration

MD485 RS-485 Multidrop Interface • In most instances, no termination is required. • If large ground potentials exist, use optical isolation. (B&

Pagina 15

MD485 RS-485 Multidrop Interface 16

Pagina 16 - To Wall Transformer

Appendix A. Phone to MD485 Network It is possible to access an MD485 network via telephone when the network is miles from the PC. See Figure A-1.

Pagina 17 - 5.2 MD9 Emulation

Appendix A. Phone to MD485 Network 1. HARDWARE REQUIREMENTS a. MD485s b. COM220 c. PS100 with A100 d. Transformer (CSI Item # 9591) or solar panel

Pagina 18 - 5.3 PakBus Networking

Appendix A. Phone to MD485 Network 3. MD9 EMULATION (POINT-TO-MULTIPOINT) PC-Modem ----COM220-PS100 with A100-MD485 ----------MD485-DL1 ----------M

Pagina 19 - 8. Wiring Specifications

Appendix A. Phone to MD485 Network FIGURE A-2. LoggerNet Phone to MD485 MD9 Emulation Setup MD485 Configuration a. Base MD485 1) Active Ports –

Pagina 20 - 8.5 Summary

Appendix A. Phone to MD485 Network COM220 and the base MD485 CS I/O port. Connect the site phone line to COM220. Connect power to PS100. When you

Pagina 21

Appendix A. Phone to MD485 Network A-6 This is a blank page.

Pagina 22

Appendix B. RF401 to MD485 Network Where an RF401 to MD485 network is desired, the following configurations will provide access to an MD485 network v

Pagina 23 - PS100 12V POWER SUPPLY

MD485 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for

Pagina 24

Appendix B. RF401 to MD485 Network 1. HARDWARE REQUIREMENTS a. MD485s b. RF401s c. PS100 with A100 d. Transformer (CSI Item #15966) for base RF401

Pagina 25 - ----------MD485-DL2

Appendix B. RF401 to MD485 Network 3. MD9 EMULATION (POINT-TO-MULTIPOINT) PC-RF401 ----RF401-PS100 with A100-MD485 ----------MD485-DL1 ----------

Pagina 26

Appendix B. RF401 to MD485 Network MD485 Configuration a. Base MD485 1) Active Ports – “CS I/O and RS-485” 2) Communication Mode – “MD9 Emula

Pagina 27

Appendix B. RF401 to MD485 Network 2. TRANSPARENT COMMUNICATION (POINT-TO-POINT) PC-RF401----RF401--null modem--MD485---MD485-DL LoggerNet Setup a. S

Pagina 28 - This is a blank page

Appendix B. RF401 to MD485 Network b. ComPort_1 – default settings c. MD9Base – defaults d. MD9Remote – Address: “1“ e. MD9Remote_2 –

Pagina 29

Appendix B. RF401 to MD485 Network FIGURE B-3. LoggerNet PakBus Networking Setup MD485 Configuration a. Base MD485 1) Active Ports – “RS-232 a

Pagina 30

Appendix B. RF401 to MD485 Network B-8 5. HARDWARE After configuring LoggerNet or PC208W, the RF401s and the MD485s you are ready to set up hardware.

Pagina 31 - ----------MD485-DL2

Appendix C. MD485 to RF401 Network Where an MD485 to RF401 network is desired, the following configurations will provide access to an RF401 network v

Pagina 32

Appendix C. MD485 to RF401 Network 1. HARDWARE REQUIREMENTS a. MD485s b. RF401s c. PS100 with A100 d. Transformer (CSI Item #15966) for base MD485

Pagina 33 - -----------MD485-DL2

Appendix C. MD485 to RF401 Network 3. MD9 EMULATION PC-MD485----MD485-PS100 with A100-RF401---RF401-DL LoggerNet Setup a. Setup: ComPort_1 MD9Base

Pagina 34

MD485 Table of Contents C. MD485 to RF401 Network ...C-1 C.1 Connection using a PS100 with A100...

Pagina 35

Appendix C. MD485 to RF401 Network When you turn on the PS100 supply, the MD485 and the RF401 receive 12V power and you will see the LEDs light in th

Pagina 36

Appendix C. MD485 to RF401 Network b. Remote MD485 1) Active Ports – “RS-232 and RS-485” 2) Communication Mode – “Transparent Communication”

Pagina 37

Appendix C. MD485 to RF401 Network RF401 Configuration The RF401s may be left in their default settings. However, if there is a neighboring RF401 ne

Pagina 38

Appendix C. MD485 to RF401 Network 4. HARDWARE After configuring LoggerNet or PC208W, the RF401s and the MD485s you are ready to set up hardware. Co

Pagina 39

Appendix C. MD485 to RF401 Network C-8 This is a blank page.

Pagina 40

Appendix D. Digital Cellular Modem to MD485 Network It is possible to access an MD485 network via a digital cellular modem when the network is miles

Pagina 41

Appendix D. Digital Cellular Modem to MD485 Network 2. TRANSPARENT COMMUNICATION (POINT-TO-POINT) PC--—Cell Tower--Raven—null modem—MD485—MD485-DL

Pagina 42

Appendix D. Digital Cellular Modem to MD485 Network 3. MD9 EMULATION (POINT-TO-MULTIPOINT) PC--—Cell Tower--Raven—null modem—MD485----MD485-DL1

Pagina 43

Appendix D. Digital Cellular Modem to MD485 Network b. IPPort – Internet IP address/domain name and the Port number (the Raven template file configu

Pagina 44

Appendix D. Digital Cellular Modem to MD485 Network 2. TRANSPARENT COMMUNICATION PC-Modem----Cell Tower Redwing-null modem-MD485-MD485-DL LoggerNet

Pagina 45 - Cellular Modems

MD485 Table of Contents Tables 1. Specifications...1 2. L

Pagina 46

Appendix D. Digital Cellular Modem to MD485 Network c. TAPIRemote – input digital cellular modem's phone number d. MD9Base – defaults e.

Pagina 47

Appendix D. Digital Cellular Modem to MD485 Network b. Remote MD485s 1) Active Ports – “CS I/O and RS-485” 2) Communication Mode – “MD9 Emulati

Pagina 48

Appendix D. Digital Cellular Modem to MD485 Network FIGURE D-3. LoggerNet Digital Cellular Modem to MD485 PakBus Networking Setup MD485 CONFIGURATI

Pagina 49 - ------MD485-DL2

Appendix D. Digital Cellular Modem to MD485 Network Remote MD485s normally connect to datalogger CS I/O ports via SC12 cables. Powering up the datal

Pagina 50

Appendix D. Digital Cellular Modem to MD485 Network D-10 This is a blank page.

Pagina 51

Appendix E. NL100 to MD485 Network It is possible to access an MD485 network via a TCP/IP network using an NL100. See Figure E-1. To wall transfor

Pagina 52

Appendix E. NL100 to MD485 Network b. IPPort – Internet IP Address – NL100 IP address : NL100 RS-485 serial server port number. (The NL100 RS-485

Pagina 53

Appendix E. NL100 to MD485 Network PC -------NL100-------MD485 ----------MD485-DL1 -----------MD485-DL2 LoggerNet Setup a. Setup: IPPort MD9Base

Pagina 54

Appendix E. NL100 to MD485 Network 4. PAKBUS NETWORKING PC ---------------NL100 ----------MD485-DL1 -----------MD485-DL2 LoggerNet Setup a. Setup:

Pagina 55 - To TCP/IP Network

Appendix E. NL100 to MD485 Network FIGURE E-3. LoggerNet NL100 to MD485 PakBus Networking Setup MD485 Configuration 5) Active Ports – “CS I/O an

Pagina 56

MD485 Table of Contents iv

Pagina 57 - -----------MD485-DL2

Appendix E. NL100 to MD485 Network E-6 5. HARDWARE After configuring LoggerNet or PC208W, the NL100 and the MD485(s), you are ready to set up hardwar

Pagina 58

Appendix F. MD485 to CC640 Digital Camera The MD485 is used with the CC640 Digital Camera when the distance between the datalogger is greater than 25

Pagina 59

Appendix F. MD485 to CC640 Digital Camera F-2 This is a blank page.

Pagina 60

Appendix G. MD485 to AVW200 Interface The MD485 is used with the AVW200 Interface for situations where wireless communication is impractical and the

Pagina 61

Appendix G. MD485 to AVW200 Interface MD485 Configuration Each MD485 in the network must be configured with the following settings (see Figure G-2):

Pagina 62

Appendix H. MD485 Port Pin Descriptions CS I/O Port The CS I/O port is Campbell Scientific's input/output port. It is not a standard RS-232 pin

Pagina 63 - Interface

Appendix H. MD485 Port Pin Descriptions H-2 RS-232 CONNECTOR, 9-PIN D-SUB FEMALE PIN I/O FUNCTION 1 +5V DCD 2 O RXD 3 I TXD 4 NC DTR 5 GND GND 6

Pagina 65 - Descriptions

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Pagina 66

MD485 RS-485 Multidrop Interface 1. Introduction The MD485 is an intelligent RS-485 interface. It is configurable to use any two of its three interf

Pagina 67

MD485 RS-485 Multidrop Interface 3. System Components 3.1 MD485 RS-485 Multidrop Interface 3.1.1 Ground Lug The MD485 has a GND lug (see Figure 1).

Pagina 68

MD485 RS-485 Multidrop Interface 3.1.3 Configuring the MD485 The MD485 is typically configured using the Device Configuration (DevConfig) utility, wh

Comentarios a estos manuales

Sin comentarios