Pagina 1 - Wireless Sensor Network

Wireless Sensor NetworkRevision: 9/11Copyright © 2010-2011Campbell Scientific, Inc.

Pagina 2

Wireless Sensor Network station synchronizes wireless sensor measurements and polls all sensors, storing the collected measurements so that it can tra

Pagina 3 - Warranty

Wireless Sensor Network 1.3 CWS220 Wireless Infrared Radiometer The CWS220 is a Wireless Infrared Radiometer that incorporates Apogee Instrument&apos

Pagina 4 - Assistance

Wireless Sensor Network 1.4 CWS655 Wireless Water Content Reflectometer The CWS655 is based on Campbell Scientific’s CS655 water content reflectomete

Pagina 5 - Table of Contents

Wireless Sensor Network The CWS655 outputs 8 values: Volumetric water content, Bulk electrical conductivity, Dielectric permittivity, Soil temperature

Pagina 6

Wireless Sensor Network TABLE 1.5-1. CWS900 Configurations and Outputs Configuration Output Single Ended Channel 1, V Single Ended Channel 2, V

Pagina 7 - Figures

Wireless Sensor Network TABLE 1.5-2. CWS900 Wind Sensor Configurations and Outputs Configuration Output Wind Speed Average, m/s Wind Speed Maximu

Pagina 8

Wireless Sensor Network 2. Specifications 2.1 Wireless Sensor Network Radio The CWB100 and CWS sensors use a 25 mW FHSS radio. Three models are ava

Pagina 9

Wireless Sensor Network 2.1.2 Typical RF Range RF range is affected by antenna height and by obstacles between the two antennae. The following range

Pagina 10

Wireless Sensor Network 2.1.5 Antenna Options All CWS wireless sensors contain a built-in 0 dBd 1/4 wave antenna. No other antenna options are availa

Pagina 11

Wireless Sensor Network Terminal Block Connector: Bi-Directional Serial datalogger connection USB Port: Computer connection for configuration Antenn

Pagina 13

Wireless Sensor Network 2.3.2 CWS220 Electrical Specifications Power: 2 AA Batteries Average Current Drain: 300 μA with 15 minute polling Radio: Int

Pagina 14

Wireless Sensor Network 2.4.3 CWS655 Environmental Specifications Temperature Range: -25° to +50°C (-13° F to + 122°F) Humidity Range: 0 to 100% W

Pagina 15

Wireless Sensor Network 2.5.3 CWS900 Environmental Specifications Temperature Range: -25° to +50°C (-13°F to + 122°F) Humidity Range: 0 to 100% Wea

Pagina 16 - 2. Specifications

Wireless Sensor Network FIGURE 3.1-1. A205 CWS to PC Interface FIGURE 3.1-2. Connection of A205 3.1.2 Required Cables A data cable, CSI part num

Pagina 17 - 2.1.3 RSSI

Wireless Sensor Network 3.1.3 Configuration CD A Configuration CD ships with each CWB100 Wireless Base Station. The CD has software and files needed

Pagina 18 - 2.2 CWB100 Specifications

Wireless Sensor Network are specified. As the network is being designed, Wireless Sensor Planner automatically determines many individual device set

Pagina 19 - 2.3 CWS220 Specifications

Wireless Sensor Network 3.2.3.1 Simple WSN Example In this example, a CWB100 base station communicates with a CWS655 and a CWS900 with a 109-L-CWS te

Pagina 20 - 2.4 CWS655 Specifications

Wireless Sensor Network Adding Communication Links to Devices The next step is to add links between the base station and the other two devices. Th

Pagina 21 - 2.5 CWS900 Specifications

Wireless Sensor Network To add the link from the CWB100 to the CWS900, select the CWB100 and drag the resulting line to the CWS900. Another Add Link

Pagina 22 - Network

Wireless Sensor Network The Radio ID may be left blank and will be filled in automatically when the device is programmed. Use the Measurement Configu

Pagina 23 - 3.1.2 Required Cables

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Pagina 24 - 3.1.5 Driver Installation

Wireless Sensor Network shown. To save these settings in a XML file for future reference, click Save and choose a filename. To send these settings t

Pagina 25

Wireless Sensor Network 3.3.2 Configuring the CWS655 To configure the CWS655 Water Content Reflectometer, first connect the A205 to the type B USB co

Pagina 26

Wireless Sensor Network 3.3.3 Configuring the CWS900 To configure the CWS900 Wireless Sensor Interface, first connect the A205 to the type B USB conn

Pagina 27

Wireless Sensor Network transmitted by wireless sensors. See Section 4.2.1 for more information on the format and use of the configuration string. Af

Pagina 28

Wireless Sensor Network Determining Size of the Array In this example the WSN includes a CWS655 and a CWS900 configured to measure a 109 temperature p

Pagina 29

Wireless Sensor Network Finishing the Program Add a one minute data table and CallTable instruction to complete the program Public WSN(12) DataTable

Pagina 30

Wireless Sensor Network Power the CWS sensors by attaching the battery pack to the 4-pin connector. The red LED light will hold steady for about 4 se

Pagina 31

Wireless Sensor Network 3.9.2 Connecting Sensors to the CWS900 For sensors that are compatible with the CWS900 but do not have the –LWS connector opt

Pagina 32

Wireless Sensor Network TABLE 4.1-1. Values Transmitted by CWS Sensors Sensor Values Transmitted CWS220 Wireless Infrared Radiometer 5 CWS655 Wirel

Pagina 33

Wireless Sensor Network Configuration: The Configuration parameter is an optional constant string parameter that specifies a list of sensor descripti

Pagina 34

Assistance Products may not be returned without prior authorization. The following contact information is for US and International customers residing

Pagina 35

Wireless Sensor Network discovered. This can make it difficult to use specific values in the datalogger program because of uncertainty as to which po

Pagina 36 - 3.9 Physical Connections

Wireless Sensor Network 4.3 ArrayIndex() Instruction The ArrayIndex function is used to return the index of a named element in an array which would o

Pagina 37 - 4.1 Array Declaration

Wireless Sensor Network in the array for program use regardless of the order in which the sensor was discovered. CRBasic instruction Fieldnames is use

Pagina 38 - 4.2 CWB100() Instruction

Wireless Sensor Network Port: The Port parameter is a constant indicating the control port (C1, C3, C5, or C7) to which the CWB100 Data line is conne

Pagina 39 - 4.2.1 Configuration String

Wireless Sensor Network Example 4.6-1. Program for Wireless Sensor Network Const NumVals = 4 'Values returned by CWS900 Public GetRSSI As Boole

Pagina 40 - 4.2.3 Status Monitoring

Wireless Sensor Network 5. CWS Button and LED Behavior The Setup button on the back of a CWS sensor and the RED and BLUE LED lights provide diagnosti

Pagina 41

Wireless Sensor Network 2. If the initial attempt fails to link to the base station, the CWS sensor will delay 5 minutes before attempting to link

Pagina 42

Wireless Sensor Network up whenever a measurement is taken and the red LED will light up whenever the measurements are transmitted to the base station

Pagina 43 - 4.6 Program Example

Wireless Sensor Network Prior to sensor discovery, the numeric monitor will display the name of the public variable specified in the CWB100 instru

Pagina 44

Wireless Sensor Network Distilled water or alcohol works well for most dust/dirt. Salt deposits dissolve better in a weak acid solution (~0.1 molar).

Pagina 45 - 5.2 Sensor Battery Voltage

Wireless Sensor Network Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat®

Pagina 46 - 6. Testing the Network

Wireless Sensor Network 8. Troubleshooting Symptom Possible Cause Solution Cannot connect to CWB100 with USB cable Wrong serial port number specifi

Pagina 47

Wireless Sensor Network Symptom Possible Cause Solution Pressing Setup button for 8-10 seconds does not initiate auto-discovery (Blue LED does not b

Pagina 48 - 7. Maintenance

Wireless Sensor Network 44 Symptom Possible Cause Solution First element in destination array specified in CWB100 instruction is -3 and all other el

Pagina 49

Appendix A. Using DevConfig for CWS Setup CWS Sensors can be configured using Device Configuration Utility, DevConfig, which can be downloaded from w

Pagina 50 - 8. Troubleshooting

Appendix A. Using DevConfig for CWS Setup 5. Once DevConfig connects to the sensor, enter the address of the CWB100 in the field called Base Station

Pagina 51

Appendix A. Using DevConfig for CWS Setup 7. If configuring a CWS900 sensor module, you can use DevConfig to ensure that the sensor is correctly con

Pagina 52

Appendix A. Using DevConfig for CWS Setup A-4

Pagina 53

Appendix B. Measurement Names and Meanings Default measurement names are shown in Wireless Sensor Planner, Network Planner, and DevConfig software.

Pagina 54

Appendix B. Measurement Names and Meanings B.3 CWS900 Default Names Default Name Meaning Units SE1 Single-ended DC voltage measured on pin 5 with

Pagina 55

Appendix B. Measurement Names and Meanings Default Name Meaning Units BV Battery voltage of wireless sensor Volts Ti Internal temperature of wir

Pagina 56

Wireless Sensor Network Table of Contents 3.2 Creating a Model of the WSN ... 16 3.2.1 W

Pagina 57 - Meanings

Appendix B. Measurement Names and Meanings Default Name Meaning Units RWDSD Resultant wind direction standard deviation. Vector mean wind directi

Pagina 58 - B.3 CWS900 Default Names

Appendix B. Measurement Names and Meanings Scalar mean horizontal wind speed, S: S=(Σsi)/N where in the case of orthogonal sensors: Si=(Uei2+Uni2)1/2

Pagina 59

Appendix B. Measurement Names and Meanings Standard deviation of wind direction, σ(Θu), using Campbell Scientific algorithm: σ(Θu)=81(1-U/S)1/2 The a

Pagina 60 - Calculations:

Appendix B. Measurement Names and Meanings The term, (( ') ') /ΘiisNS2∑, is 0 if the deviations in speed are not correlated with the deviat

Pagina 61

Appendix B. Measurement Names and Meanings B-8

Pagina 62

Appendix C. Battery Life C.1 Battery Characteristics The battery life of the CWS wireless sensors is a function of the polling interval, repeater us

Pagina 63 - ()(( /)) ( /)

Appendix C. Battery Life Sensor and Connection 5 Min Polling 10 Min Polling 15 Min Polling CWS900 w/109 Probe or CWS655 15 months 21 months 24

Pagina 64

Appendix C. Battery Life In another situation, there may be a sensor in a location that permits a direct connection to the base, but misses a signif

Pagina 65 - Appendix C. Battery Life

Appendix C. Battery Life C-4

Pagina 67

Wireless Sensor Network Table of Contents B. Measurement Names and Meanings ... B-1 B.1 CWS220 Default Names...

Pagina 68

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Pagina 69

Wireless Sensor Network Table of Contents iv

Pagina 70

Wireless Sensor Network 1. Understanding a Wireless Sensor Network 1.1 General Description Why wireless? There are situations when it is desirable t