Pagina 1 - 8 Channel Interval Timer

SDM-INT88 Channel Interval TimerRevision: 12/11Copyright © 1989-2011Campbell Scientific, Inc.

Pagina 2

SDM-INT8 8 Channel Interval Timer Minimum AC Max Freq. voltage RMS (Hz) 20 mV 100 50 mV 400 150 mV 1000 2.5 V - 20 V 4000 3. Connections The

Pagina 3 - Warranty

SDM-INT8 8 Channel Interval Timer 10K OHM RESISTOR CR800, CR850, CR9032 (CR9000X), CR9080 (CR9000), CR10(X), CR23X, or CR1000 CR3000,CR5000 12VGSDM-

Pagina 4 - Assistance

SDM-INT8 8 Channel Interval Timer 5.1 CRBasic Programming 5.1.1 Instruction SDMINT8 The SDMINT8 instruction is used to program and control the SDMI

Pagina 5 - SDM-INT8 Table of Contents

SDM-INT8 8 Channel Interval Timer Function8_5: The Function8_5 parameter is a four digit code used to program the timing function of channels 5 throu

Pagina 6

SDM-INT8 8 Channel Interval Timer as a trigger to start making measurements. The Dest parameter must be dimensioned large enough to receive the captu

Pagina 7

SDM-INT8 8 Channel Interval Timer The equation used to calculate the bit rate depends on the datalogger used. The datalogger will round down to the

Pagina 8 - 1. Overview

SDM-INT8 8 Channel Interval Timer TABLE 2. Instruction 101 Parameter Data Description Type 01: 2 Address (Section 6.1) 02: 4 *Input config; c

Pagina 9 - 2. Specifications

SDM-INT8 8 Channel Interval Timer connected to the datalogger must have a unique address. See Appendix A for details on changing the address. 6.2 I

Pagina 10 - 3. Connections

SDM-INT8 8 Channel Interval Timer 6 - Low resolution frequency (kHz)-- For this function to return low resolution data, it must be the only function

Pagina 11 - RESISTOR

SDM-INT8 8 Channel Interval Timer Channel 1: frequency (2) Channel 3: counts on channel 2 since channel 1 (5) Channel 4: frequency (2) Channel 5:

Pagina 13

SDM-INT8 8 Channel Interval Timer TABLE 3. Input Frequency (kHz) at Which Processing Time Equals Measuring/Storing Time N 1,2,6,7 3 4 5 8

Pagina 14 - 5.1.2 SDMSpeed Instruction

SDM-INT8 8 Channel Interval Timer TABLE 4. Sampling Interval (Seconds) to Accumulate 8000 Unprocessed Events for Functions 1,2,6,7 Input Number of

Pagina 15

SDM-INT8 8 Channel Interval Timer FIGURE 4. Example of Multiple Beginnings and Endings 6.4.2 Option 0: Execution Interval Averaging When Option 0

Pagina 16 - 6. Programming Details

SDM-INT8 8 Channel Interval Timer Assume the input frequency is 0.5 Hz, and the execution interval of Instruction 101 is 10 Hz. The datalogger input

Pagina 17 - 6.2 Input Configuration

SDM-INT8 8 Channel Interval Timer Since the number of values returned may be variable, making it difficult to assign a fixed number of input location

Pagina 18

SDM-INT8 8 Channel Interval Timer TABLE 5. Definition of Test Memory Option Output Output Definition positive integer = ROM signature, good RAM n

Pagina 19 - 6.4 Output Option

SDM-INT8 8 Channel Interval Timer When using the Capture All Events Option (no averaging), the data are directed to Final Storage of the datalogger r

Pagina 20 -

SDM-INT8 8 Channel Interval Timer ‘Declare Public Variables Public Int8(5) Public PulseCh(2) Dim I ‘Define Data Tables DataTable (Dat5min,1,-1) Dat

Pagina 21

SDM-INT8 8 Channel Interval Timer Parameter 6 (Capture All Events) is programmed for 20--to capture edge times on channels 1-5 until 20 edges are rec

Pagina 22

SDM-INT8 8 Channel Interval Timer 3: Beginning of Loop (P87) loop to make a 10 sec. 1: 1 Delay delay 2: 20 Loop Count 4: End (P95)

Pagina 23 - Edges On Channel 1

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Pagina 24

SDM-INT8 8 Channel Interval Timer *Table 1 Programs 01: 1 Sec. Execution interval 1: SDM-INT8 (P101) measure wind speed 1: 00 Address Optio

Pagina 25 - 6.6 Edlog Output Format

SDM-INT8 8 Channel Interval Timer *Table 1 Programs 01: .125 Sec. Execution interval 1: If Flag/Port (P91) 1: 21 Do if flag 1 is low 2:

Pagina 26 - 7. Program Examples

SDM-INT8 8 Channel Interval Timer 26 11: Set Active Storage Area (P80) 1: 1 Final Storage Area 1 2: 1 Array ID or location 12: Sample

Pagina 27 - 7.2 Edlog Program Examples

Appendix A. Address Jumper The address is factory set at address 00. Figure A1 (also shown inside the INT8 cover) shows the 16 possible positions an

Pagina 29

Appendix B. Processing Time Limitations With the exception of the Capture All Events Option or when all channels are programmed for low resolution fr

Pagina 30 - Burst Mode

Appendix B. Processing Time Limitations If the Tt for Output Option XXXX is greater than the specified interval, the extra time will be added to the

Pagina 31

Appendix B. Processing Time Limitations Example 3 Given: N = number of channels measured F = Frequency of input signal, kHz Function = frequenc

Pagina 32

Appendix B. Processing Time Limitations B-4

Pagina 33 - Appendix A. Address Jumper

Appendix C. INT8 Input Schematic C-1

Pagina 34

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Pagina 37

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Pagina 38

SDM-INT8 Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links

Pagina 39

SDM-INT8 Table of Contents ii Appendices A. Address Jumper ... A-1 B. Processing Time Limitations

Pagina 40

SDM-INT8 8 Channel Interval Timer FIGURE 1. SDM-INT8 Front Panel 1

Pagina 41

SDM-INT8 8 Channel Interval Timer 1. Overview The 8 channel Interval Timer (INT8; see Figure 1) is a measurement module which outputs processed timi

Pagina 42

SDM-INT8 8 Channel Interval Timer 2. Specifications Operating voltage: 9.6 V to 16 V DC Current drain: 13 to 20 mA active, 400 microamp quiescent