CURS100 100 Ohm Current
Shunt Terminal Input Module
Revision: 7/13
Copyright © 1996-2013
Campbell Scientific, Inc.
Vista de pagina 0
1 2 3 4 5 6 ... 17 18

Indice de contenidos

Pagina 1 - Shunt Terminal Input Module

CURS100 100 Ohm Current Shunt Terminal Input ModuleRevision: 7/13 Copyright © 1996-2013Campbell Scientific, Inc.

Pagina 2

CURS100 100 Ohm Current Shunt Terminal Input Module Signal From SensorSensor Cable ShieldSensor PowerJumper FIGURE 3-1. CURS100 L terminal connected

Pagina 3 - Warranty

CURS100 100 Ohm Current Shunt Terminal Input Module Datalogger TransducerIHLG+12 VSignalPower FIGURE 4-1. 2-wire with datalogger power Datalogger Tr

Pagina 4 - Assistance

CURS100 100 Ohm Current Shunt Terminal Input Module transducer and everything is fine. However, if the battery voltage drops to 11 volts, a 20 mA cu

Pagina 5 - Table of Contents

CURS100 100 Ohm Current Shunt Terminal Input Module Datalogger TransducerIHLGSignalPowerBattery–+Ground FIGURE 4-5. 3-wire with external power 4.3

Pagina 6

CURS100 100 Ohm Current Shunt Terminal Input Module 5. Sensor and Programming Example In this example, the input voltage range, and the multiplier a

Pagina 7 - Terminal Input Module

CURS100 100 Ohm Current Shunt Terminal Input Module and at 700 psi is: V = 0.020 × 100 V = 2.0 V or 2000 mV Since the datalogger measures in mV, the

Pagina 8 - 3. Measurement Concepts

CURS100 100 Ohm Current Shunt Terminal Input Module 10 BeginProg Scan (1,Sec,1,0) 'Generic 4-20 mA Input measurement Measure: VoltDiff (Measu

Pagina 10 - 4. Transducer Wiring

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Pagina 12 - 4.2 Three-Wire Transducers

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Pagina 13 - 4.3 Four-Wire Transducers

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Pagina 14 - 5.1 Voltage Range

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Pagina 16 - 5.5 CR10(X) Program Example

CURS100 100 Ohm Current Shunt Terminal Input Module 1. Introduction Terminal input modules connect directly to the datalogger’s input terminals to

Pagina 17

CURS100 100 Ohm Current Shunt Terminal Input Module DataloggerRshunt100 Ω± 0.01%HLor Gor AGHLCURS100 FIGURE 2-1. CURS100 schematic The CURS100 has t

Pagina 18

CURS100 100 Ohm Current Shunt Terminal Input Module 3.1 Differential Measurement The voltage across the completion resistor is measured with the dif